Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J. pediatr. (Rio J.) ; 95(6): 674-681, Nov.-Dec. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1056656

RESUMO

ABSTRACT Objective: The objective of this study was to develop and validate a computational tool to assist radiological decisions on necrotizing enterocolitis. Methodology: Patients that exhibited clinical signs and radiographic evidence of Bell's stage 2 or higher were included in the study, resulting in 64 exams. The tool was used to classify localized bowel wall thickening and intestinal pneumatosis using full-width at half-maximum measurements and texture analyses based on wavelet energy decomposition. Radiological findings of suspicious bowel wall thickening and intestinal pneumatosis loops were confirmed by both patient surgery and histopathological analysis. Two experienced radiologists selected an involved bowel and a normal bowel in the same radiography. The full-width at half-maximum and wavelet-based texture feature were then calculated and compared using the Mann-Whitney U test. Specificity, sensibility, positive and negative predictive values were calculated. Results: The full-width at half-maximum results were significantly different between normal and distended loops (median of 10.30 and 15.13, respectively). Horizontal, vertical, and diagonal wavelet energy measurements were evaluated at eight levels of decomposition. Levels 7 and 8 in the horizontal direction presented significant differences. For level 7, median was 0.034 and 0.088 for normal and intestinal pneumatosis groups, respectively, and for level 8 median was 0.19 and 0.34, respectively. Conclusions: The developed tool could detect differences in radiographic findings of bowel wall thickening and IP that are difficult to diagnose, demonstrating the its potential in clinical routine. The tool that was developed in the present study may help physicians to investigate suspicious bowel loops, thereby considerably improving diagnosis and clinical decisions.


RESUMO Objetivo: O objetivo deste estudo foi desenvolver e validar uma ferramenta computacional para auxiliar as decisões radiológicas na enterocolite necrotizante. Metodologia: Pacientes que exibiam sinais clínicos e evidências radiográficas do estágio 2 ou superior de Bell foram incluídos no estudo, que resultou em 64 exames. A ferramenta foi usada para classificar o aumento localizado da espessura da parede intestinal e a pneumatose intestinal com medidas de largura total a meia altura e análises de textura baseadas na decomposição da energia wavelet. Os achados radiológicos de aumento suspeito da espessura da parede intestinal e das alças na pneumatose intestinal foram confirmados pela cirurgia e análise histopatológica do paciente. Dois radiologistas experientes selecionaram um intestino afetado e um intestino normal na mesma radiografia. A largura total a meia altura e a característica da textura baseada em wavelet foram então calculadas e comparadas com o uso do teste U de Mann-Whitney. Foram calculados a especificidade, sensibilidade, valores preditivos positivos e negativos. Resultados: Os resultados da largura total a meia altura foram significativamente diferentes entre a alça normal e a distendida (mediana de 10,30 e 15,13, respectivamente). Medidas de energia wavelet horizontal, vertical e diagonal foram avaliadas em oito níveis de decomposição. Os níveis 7 e 8 na direção horizontal apresentaram diferenças significativas. Para o nível 7, as medianas foram 0,034 e 0,088 para os grupos normal e com pneumatose intestinal, respectivamente, e para o nível 8, as medianas foram 0,19 e 0,34, respectivamente. Conclusões: A ferramenta desenvolvida pode detectar diferenças nos achados radiográficos do aumento da espessura da parede intestinal e PI de difícil diagnóstico, demonstra seu potencial na rotina clínica. A ferramenta desenvolvida no presente estudo pode ajudar os médicos a investigar alças intestinais suspeitas e melhorar consideravelmente o diagnóstico e as decisões clínicas.


Assuntos
Humanos , Recém-Nascido , Enterocolite Necrosante/diagnóstico por imagem , Doenças do Recém-Nascido/diagnóstico por imagem , Índice de Gravidade de Doença , Processamento de Imagem Assistida por Computador , Validação de Programas de Computador , Radiografia Abdominal , Estudos Retrospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Análise de Ondaletas , Intestinos/fisiopatologia
2.
J Pediatr (Rio J) ; 95(6): 674-681, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31679612

RESUMO

OBJECTIVE: The objective of this study was to develop and validate a computational tool to assist radiological decisions on necrotizing enterocolitis. METHODOLOGY: Patients that exhibited clinical signs and radiographic evidence of Bell's stage 2 or higher were included in the study, resulting in 64 exams. The tool was used to classify localized bowel wall thickening and intestinal pneumatosis using full-width at half-maximum measurements and texture analyses based on wavelet energy decomposition. Radiological findings of suspicious bowel wall thickening and intestinal pneumatosis loops were confirmed by both patient surgery and histopathological analysis. Two experienced radiologists selected an involved bowel and a normal bowel in the same radiography. The full-width at half-maximum and wavelet-based texture feature were then calculated and compared using the Mann-Whitney U test. Specificity, sensibility, positive and negative predictive values were calculated. RESULTS: The full-width at half-maximum results were significantly different between normal and distended loops (median of 10.30 and 15.13, respectively). Horizontal, vertical, and diagonal wavelet energy measurements were evaluated at eight levels of decomposition. Levels 7 and 8 in the horizontal direction presented significant differences. For level 7, median was 0.034 and 0.088 for normal and intestinal pneumatosis groups, respectively, and for level 8 median was 0.19 and 0.34, respectively. CONCLUSIONS: The developed tool could detect differences in radiographic findings of bowel wall thickening and IP that are difficult to diagnose, demonstrating the its potential in clinical routine. The tool that was developed in the present study may help physicians to investigate suspicious bowel loops, thereby considerably improving diagnosis and clinical decisions.


Assuntos
Enterocolite Necrosante/diagnóstico por imagem , Doenças do Recém-Nascido/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Recém-Nascido , Intestinos/fisiopatologia , Radiografia Abdominal , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Validação de Programas de Computador , Estatísticas não Paramétricas , Análise de Ondaletas
3.
Artigo em Inglês | MEDLINE | ID: mdl-31130999

RESUMO

BACKGROUND: Background: Tuberculosis (TB) is an infectious lung disease with high worldwide incidence that severely compromises the quality of life in affected individuals. Clinical tests are currently employed to monitor pulmonary status and treatment progression. The present study aimed to apply a three-dimensional (3D) reconstruction method based on chest radiography to quantify lung-involvement volume of TB acute-phase patients before and after treatment. In addition, these results were compared with indices from conventional clinical exams to show the coincidence level. METHODS: A 3D lung reconstruction method using patient chest radiography was applied to quantify lung-involvement volume using retrospective examinations of 50 patients who were diagnosed with pulmonary TB and treated with two different drugs schemes. Twenty-five patients were treated with Scheme I (rifampicin, isoniazid, and pyrazinamide), whereas twenty-five patients were treated with Scheme II (rifampicin, isoniazid, pyrazinamide, and ethambutol). Acute-phase reaction: Serum exams included C-reactive protein levels, erythrocyte sedimentation rate, and albumin levels. Pulmonary function was tested posttreatment. RESULTS: We found strong agreement between lung involvement and serum indices pre- and posttreatment. Comparison of the functional severity degree with lung involvement based on 3D image quantification for both treatment schemes found a high correlation. CONCLUSIONS: The present 3D reconstruction method produced a satisfactory agreement with the acute-phase reaction, most notably a higher significance level with the C-reactive protein. We also found a quite reasonable coincidence between the 3D reconstruction method and the degree of functional lung impairment posttreatment. The performance of the quantification method was satisfactory when comparing the two treatment schemes. Thus, the 3D reconstruction quantification method may be useful tools for monitoring TB treatment. The association with serum indices are not only inexpensive and sensitive but also may be incorporated into the assessment of patients during TB treatment.

4.
J. venom. anim. toxins incl. trop. dis ; 25: e144918, 2019. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-984699

RESUMO

Background: Tuberculosis (TB) is an infectious lung disease with high worldwide incidence that severely compromises the quality of life in affected individuals. Clinical tests are currently employed to monitor pulmonary status and treatment progression. The present study aimed to apply a three-dimensional (3D) reconstruction method based on chest radiography to quantify lung-involvement volume of TB acute-phase patients before and after treatment. In addition, these results were compared with indices from conventional clinical exams to show the coincidence level. Methods: A 3D lung reconstruction method using patient chest radiography was applied to quantify lung-involvement volume using retrospective examinations of 50 patients who were diagnosed with pulmonary TB and treated with two different drugs schemes. Twenty-five patients were treated with Scheme I (rifampicin, isoniazid, and pyrazinamide), whereas twenty-five patients were treated with Scheme II (rifampicin, isoniazid, pyrazinamide, and ethambutol). Acute-phase reaction: Serum exams included C-reactive protein levels, erythrocyte sedimentation rate, and albumin levels. Pulmonary function was tested posttreatment. Results: We found strong agreement between lung involvement and serum indices pre- and posttreatment. Comparison of the functional severity degree with lung involvement based on 3D image quantification for both treatment schemes found a high correlation. Conclusions: The present 3D reconstruction method produced a satisfactory agreement with the acute-phase reaction, most notably a higher significance level with the C-reactive protein. We also found a quite reasonable coincidence between the 3D reconstruction method and the degree of functional lung impairment posttreatment. The performance of the quantification method was satisfactory when comparing the two treatment schemes. Thus, the 3D reconstruction quantification method may be useful tools for monitoring TB treatment. The association with serum indices are not only inexpensive and sensitive but also may be incorporated into the assessment of patients during TB treatment.(AU)


Assuntos
Humanos , Masculino , Tuberculose Pulmonar/terapia , Tomografia Computadorizada por Raios X/instrumentação , Lesão Pulmonar/reabilitação , Testes de Função Respiratória/métodos , Proteína C/análise , Biomarcadores
5.
Am J Otolaryngol ; 39(4): 431-435, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29685378

RESUMO

BACKGROUND AND OBJECTIVES: Imaging exams play a key role in cochlear implants with regard to both planning implantation before surgery and quality control after surgery. The ability to visualize the three-dimensional location of implanted electrodes is useful in clinical routines for assessing patient outcome. The aim of this study was to evaluate linear and angular insertion depth measurements of cochlear implants based on conventional computed tomography. METHODS: Tools for linear and angular measurements of cochlear implants were used in computed tomography exams. The tools realized the insertion measurements in an image reconstruction of the CIs, based on image processing techniques. We comprehensively characterized two cochlear implant models while obviating possible changes that can be caused by different cochlea sizes by using the same human temporal bones to evaluate the implant models. RESULTS: The tools used herein were able to differentiate the insertion measurements between two cochlear implant models widely used in clinical practice. We observed significant differences between both insertion measurements because of their different design and construction characteristics (p = 0.004 and 0.003 for linear and angular measurements, respectively; t-test). The presented methodology showed to be a good tool to calculate insertion depth measurements, since it is easy to perform, produces high-resolution images, and is able to depict all the landmarks, thus enabling measurement of the angular and linear insertion depth of the most apical electrode contacts. CONCLUSION: The present study demonstrates practical and useful tools for evaluating cochlear implant electrodes in clinical practice. Further studies should measure preoperative and postoperative benefits in terms of speech recognition and evaluate the preservation of residual hearing in the implanted ear. Such studies can also determine correlations between surgical factors, electrode positions, and performance. In addition to refined surgical techniques, the precise evaluation of cochlear length and correct choice of cochlear implant characteristics can play an important role in postoperative outcomes.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X
6.
PLoS One ; 13(1): e0190770, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29304130

RESUMO

Volume measurements of maxillary sinus may be useful to identify diseases affecting paranasal sinuses. However, literature shows a lack of consensus in studies measuring the volume. This may be attributable to different computed tomography data acquisition techniques, segmentation methods, focuses of investigation, among other reasons. Furthermore, methods for volumetrically quantifying the maxillary sinus are commonly manual or semiautomated, which require substantial user expertise and are time-consuming. The purpose of the present study was to develop an automated tool for quantifying the total and air-free volume of the maxillary sinus based on computed tomography images. The quantification tool seeks to standardize maxillary sinus volume measurements, thus allowing better comparisons and determinations of factors that influence maxillary sinus size. The automated tool utilized image processing techniques (watershed, threshold, and morphological operators). The maxillary sinus volume was quantified in 30 patients. To evaluate the accuracy of the automated tool, the results were compared with manual segmentation that was performed by an experienced radiologist using a standard procedure. The mean percent differences between the automated and manual methods were 7.19% ± 5.83% and 6.93% ± 4.29% for total and air-free maxillary sinus volume, respectively. Linear regression and Bland-Altman statistics showed good agreement and low dispersion between both methods. The present automated tool for maxillary sinus volume assessment was rapid, reliable, robust, accurate, and reproducible and may be applied in clinical practice. The tool may be used to standardize measurements of maxillary volume. Such standardization is extremely important for allowing comparisons between studies, providing a better understanding of the role of the maxillary sinus, and determining the factors that influence maxillary sinus size under normal and pathological conditions.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Seio Maxilar/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Adulto , Algoritmos , Feminino , Humanos , Imageamento Tridimensional/métodos , Modelos Lineares , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Quant Imaging Med Surg ; 7(3): 318-325, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28811998

RESUMO

BACKGROUND: The purpose of the present study was to evaluate differences in lung damage in patients with paracoccidioidomycosis (PCM) in two endemic regions of Brazil (Botucatu, SP, in the southeastern region and Campo Grande, MS, in the west central region). METHODS: The study sought to objectively quantify fibrosis and emphysema treated patients using high-resolution computed tomography (HRCT) that was performed according to an established and validated computational method. The analysis was based on clinical data that were associated with objective quantifications of pulmonary sequelae. We performed a retrospective analysis of HRCT exams from 32 successfully treated patients with the chronic form of PCM. The two groups had similar characteristics with regard to age, symptom duration, smoking history, and titers on a diagnostic serologic test. RESULTS: The statistical analysis revealed more severe cases and a higher percentage of emphysema in the Campo Grande group. The mean percentages of emphysema were 40.2% and 13.6% in the Campo Grande and Botucatu groups, respectively. The percentage of fibrosis was significantly higher in the Botucatu group (11.3%) than in the Campo Grande group (2.3%). CONCLUSIONS: The present results may reflect differences in cryptic species of P. brasiliensis in these two geographic regions of Brazil. Further studies should be done to clarify the differences observed herein. Such findings may help unveil differences among cryptic species in terms of the pulmonary consequences that are caused by this disease, which would be highly beneficial to PCM patients.

8.
Phys Med ; 37: 58-67, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28535916

RESUMO

PURPOSE: The aim of the present study was to determine the efficiency of six methods for calculate the effective dose (E) that is received by health professionals during vascular interventional procedures. METHODS: We evaluated the efficiency of six methods that are currently used to estimate professionals' E, based on national and international recommendations for interventional radiology. Equivalent doses on the head, neck, chest, abdomen, feet, and hands of seven professionals were monitored during 50 vascular interventional radiology procedures. Professionals' E was calculated for each procedure according to six methods that are commonly employed internationally. To determine the best method, a more efficient E calculation method was used to determine the reference value (reference E) for comparison. RESULTS: The highest equivalent dose were found for the hands (0.34±0.93mSv). The two methods that are described by Brazilian regulations overestimated E by approximately 100% and 200%. The more efficient method was the one that is recommended by the United States National Council on Radiological Protection and Measurements (NCRP). The mean and median differences of this method relative to reference E were close to 0%, and its standard deviation was the lowest among the six methods. CONCLUSIONS: The present study showed that the most precise method was the one that is recommended by the NCRP, which uses two dosimeters (one over and one under protective aprons). The use of methods that employ at least two dosimeters are more efficient and provide better information regarding estimates of E and doses for shielded and unshielded regions.


Assuntos
Exposição Ocupacional , Doses de Radiação , Monitoramento de Radiação/métodos , Radiologia Intervencionista , Pessoal de Saúde , Humanos , Proteção Radiológica
9.
PLoS One ; 11(4): e0154193, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27101001

RESUMO

Digital radiographic imaging is increasing in veterinary practice. The use of radiation demands responsibility to maintain high image quality. Low doses are necessary because workers are requested to restrain the animal. Optimizing digital systems is necessary to avoid unnecessary exposure, causing the phenomenon known as dose creep. Homogeneous phantoms are widely used to optimize image quality and dose. We developed an automatic computational methodology to classify and quantify tissues (i.e., lung tissue, adipose tissue, muscle tissue, and bone) in canine chest computed tomography exams. The thickness of each tissue was converted to simulator materials (i.e., Lucite, aluminum, and air). Dogs were separated into groups of 20 animals each according to weight. Mean weights were 6.5 ± 2.0 kg, 15.0 ± 5.0 kg, 32.0 ± 5.5 kg, and 50.0 ± 12.0 kg, for the small, medium, large, and giant groups, respectively. The one-way analysis of variance revealed significant differences in all simulator material thicknesses (p < 0.05) quantified between groups. As a result, four phantoms were constructed for dorsoventral and lateral views. In conclusion, the present methodology allows the development of phantoms of the canine chest and possibly other body regions and/or animals. The proposed phantom is a practical tool that may be employed in future work to optimize veterinary X-ray procedures.


Assuntos
Imagens de Fantasmas/veterinária , Doses de Radiação , Radiografia Torácica/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Cães , Radiografia Torácica/métodos , Reprodutibilidade dos Testes , Tórax , Tomografia Computadorizada por Raios X/métodos , Medicina Veterinária/métodos , Raios X
10.
Medicine (Baltimore) ; 94(26): e1044, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26131814

RESUMO

The purpose of this work was to develop a quantitative method for evaluating the pulmonary inflammatory process (PIP) through the computational analysis of chest radiography exams in posteroanterior (PA) and lateral views. The quantification procedure was applied to patients with tuberculosis (TB) as the motivating application.A study of high-resolution computed tomography (HRCT) examinations of patients with TB was developed to establish a relation between the inflammatory process and the signal difference-to-noise ratio (SDNR) measured in the PA projection. A phantom essay was used to validate this relation, which was implemented using an algorithm that is able to estimate the volume of the inflammatory region based solely on SDNR values in the chest radiographs of patients.The PIP volumes that were quantified for 30 patients with TB were used for comparisons with direct HRCT analysis for the same patient. The Bland-Altman statistical analyses showed no significant differences between the 2 quantification methods. The linear regression line had a correlation coefficient of R = 0.97 and P < 0.001, showing a strong association between the volume that was determined by our evaluation method and the results obtained by direct HRCT scan analysis.Since the diagnosis and follow-up of patients with TB is commonly performed using X-rays exams, the method developed herein can be considered an adequate tool for quantifying the PIP with a lower patient radiation dose and lower institutional cost. Although we used patients with TB for the application of the method, this method may be used for other pulmonary diseases characterized by a PIP.


Assuntos
Radiografia Torácica/métodos , Tuberculose Pulmonar/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Melhoria de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...